Overview process calibrator
Process calibrator, the signal source. Process calibrator is divided into pressure calibration, multi-function validator, temperature calibration, the calibration loop / process Qianbiao / process multimeter, loop calibrator, the main function for measuring sensors, transmission And other instruments of voltage, current (mA), RTD, thermocouple, frequency and resistance, the output / analog transmitter calibration required voltage, current (mA), thermocouple, RTD, frequency, resistance, And pressure. Current measurement of the loop at the same time provide power transformers. Pressure
process calibrator b> with the pressure measurement modules / output pressure, loop calibrator can mA source, simulation and measurement
Knowledge of the process calibrator
Applicable to the Process calibrator and the need for inspection equipment, extensive resources / measuring instruments in this field, sensors and equipment require substantial operational inspection. TL925 portable calibrator is a process structure, light weight, multi-checking function of the apparatus, can be a source and measure voltage, current, resistance, TC, RTD, frequency and pulse measurement of the signal at the same time. TL925 portable process calibrator b> is the basis of a model, in addition to TC and RTD measurements and communications functions, and other features CA71 same.
At the same time the process calibrator signal and measurement capability to when the problem occurred, TL925 process calibrator can also detect normal thermocouple (TC), heat resistance (RTD) and a variety of other types of sensors and equipment. (Thermocouple (TC) and heat resistance (RTD) measurements limited to CA71)
AC voltage process calibrator (including the power supply voltage) measurement capability: for example, in the process calibrator of the instrument panel, the functioning of the large number of signal converters and other equipment, portable process calibrator can detect each of input and equipment And the output signal could be detected at the same time power supply, no separate multimeter measuring supply voltage. Process calibrator variety of useful features
Source: 4-20 mA current, 24 V DC DC power supply. Communication process calibrator (only CA71): compatible with RS-232C interface. Step-by-step process calibrator output (n / m) feature: Set step-by-step output, from the trouble calculated as a percentage of output. Stepping automatic process calibrator features: step-by-step through the output (n / m) feature set, the output value of stepping change. 10% or 25% step will automatically change
Calibrator scanning process: linear value increased or decreased output. Rise and fall times set in between 16 or 32 seconds. Process calibrator memory function: can the portable calibrator in the preservation of memory or read in value and the measurement data. (Set Max 50) process calibrator is simple: a portable process calibrator function switch, simple operation. Open the box and connect portable test line, you can prepare measurement